Page view 114
This screenshot lists iSCSI target volumes created under thin-provisioning. The 2
nd
iSCSI target volume under thin-provisioning has been created with a capacity of
14300GB.
This message appears if there is no more room for new iSCSI target creation.
iSCSI LUN ID
NOTE
1. Each RAID volume can only create one iSCSI thin-provision volume.
2. Each thin-provision volume can only create 5 iSCSI target volumes.
3. The notification will send out while the physical size of iSCSI
thin-provision capacity has used up to 90%.
When iSCSI target volume has been created, there is a default LUN ID of 0 in
previous firmware versions which was un-configurable. From v3.00.04, it is
configurable from 1 to 254 with a default of the next available number in ascending
numerical order. The LUN ID is unique and can not be duplicated except for LUN ID
0.